Test | Test Point | Method #1 - HP-4300A Electronic Voltmeter | Method #2 - 15 MHz Scope |
---|---|---|---|
Carrier Level (No audio in) |
LINE MON (BNC) | 25 mV rms Term in 75 ohms | 150 mV P-P (unterm) |
If not, adust R34 on board | |||
Level (with +8 dBm @ 1 kHz audio in) |
INPUT MON (BNC) | 970-1000 mV rms (unterm) | 2.8 V P-P (unterm) |
No adjustment, if wrong, check input termination strapping | |||
Deviation (with +8 dBm @ 1 kHz audio in) [200 kHz peak deviation] |
DEV MON (BNC) | 94 mV rms (unterm) | 280 mV P-P (unterm) |
If not, adjust "DEV ADJ" (front panel) |
Test | Test Point | Method #1 - HP-4300A Electronic Voltmeter | Method #2 - 15 MHz Scope |
---|---|---|---|
Level (with +8 dBm @ 1 kHz audio into transmitter) |
OUTPUT MON (BNC) | 970-1000 mV rms (unterm) | 2.8 V P-P (unterm) |
If not, adjust "LEV ADJ" (front panel) |
The author of these procedures is unknown. This page was re-typed and posted by John Neuhaus, john at jneuhaus.com, Wednesday, March 28, 2001 at 9:19 PM ET